BRIDGE SEAL |
|
|
|
Two-component, penetrating polyoxarine healer/sealer
|
|
Compliances
Federal EPA V.O.C. < 250 g/L
AASHTO T-259 Chloride Ion Penetration Resistance (90 day ponding)
Meets USDA specifications for use in food processing areas
|
|
|
|
|
 |
|
Description
Unitex BRIDGE SEAL is a two-component, fluorescent polyoxarine
sealer designed both for the protection of new concrete and for the preservation of
partially deteriorated concrete to extend its service life.
BRIDGE SEAL penetrates into the concrete pore structure to form
a sub-surface sealing layer that will effectively impede moisture intrusion and
chloride ion penetration.
|
|
Features
- Fills cracks
- Stops corrosion
- Deep penetrating
- Structurally restores concrete surface
- Safer mixing
|
 |
 |
 |
|
Uses
Bridge decks
Parking decks
Floors
Columns and beams in splash zones
Consolidation of porous and dusting surfaces
Properties
| |
Part A |
Part B |
Mixed System |
| Weight per Gal/Liter: |
8.7 lbs./4 kg |
7.7 lbs./3.5 kg |
8.2 lbs./3.7 kg |
| Viscosity |
<50 cps |
<50 cps |
<50 cps |
| Specific Gravity |
1.05 |
.93 |
.97 |
Quality Assurance
The best way to check for complete penetration of BRIDGE SEAL is to take core samples. BRIDGE SEAL contains Z18 Fluorescent Tracer Dye, which illuminates under black light. This provides evidence of penetration into the finest hairline cracks in concrete.
|
|
Application
| Step 1. |
Patch concrete with UNITEX PRO-POXY 2500 or PATCH SET 928. |
| Step 2. |
Clean concrete by abrasive or sand blasting. Surface must be clean, dry and free of frost. |
| Step 3. |
Mechanically mix 2 components 1:1 by volume with Jiffy mixer and variable speed drill 300 rpm for a minimum of 3 minutes. |
| Step 4. |
Within 5 minutes, flood coat BRIDGE SEAL onto concrete. |
| Step 5. |
Immediately distribute evenly and work into concrete for a minimum of 5 minutes for maximum penetration. Keep ponding BRIDGE SEAL into cracks until refusal. Remove all excess with a squeegee on smooth surfaces and a broom on textured surfaces. Surface should appear damp but with no film build-up or ponding prior to broadcast. |
| Step 6. |
Broadcast oven-dried silica sand to refusal. |
| Step 7. |
After initial cure, remove excess sand. |
|
 |
 |
 |
|
Advantages of BRIDGE SEAL
| |
BRIDGE SEAL |
Urethane Deck Coatings |
Siloxanes / Silanes |
3 Component HMWMMA's |
Linseed Oils |
| Bond Strength |
Excellent |
Fair |
None |
Poor |
None |
| Tensile Strength |
Excellent |
Poor |
N/A |
Fair |
N/A |
| Waterproofs Surface |
Excellent |
Good |
Good |
Good |
Fair |
| Fills Cracks |
Excellent |
Fair |
None |
Good |
None |
Volatile when Improperly Mixed |
No |
No |
N/A |
Yes |
N/A |
| Moisture Sensitive |
No |
Yes |
Yes |
Yes |
Yes |
 |
 |
 |
 |
 |
 |
|
 |
 |
 |
|
Coverage
Broom-finished Concrete:*
65-100 sq. ft./gal or
6.0-9.3 sq. m/L
Steel-troweled concrete:*
150-200 sq. ft./gal or
13.9-18.6 sq. m/L
*Coverage rate depends on porosity of concrete.
|
|
Packaging
BRIDGE SEAL is sold:
2 gal./7.6 L units (two 1 gal. cans)
10 gal./37.8 L units (two 5 gal. pails)
110 gal./416 L units (two 55 gal. drums)
|
 |
 |
 |
|
Limitations
- Store polyoxarine BRIDGE SEAL at 50-80°F/10-27°C
- Condition polyoxarine BRIDGE SEAL to 65-80°F/18-27°C
- Minimum application temperature: 40°F/4°C
- Shelf Life: 1 year in original unopened container.
- Pot Life: Approx. 1 hr. in mass at 72°F/22°C, 20 min. in thin film at 72°F/22°C.
- Curing Time: Approx. 4 hrs. at substrate temp. of 77°F/22°C.
- Maximum of 1 flood coat application.
- Do not apply over curing compounds.
- Apply to dry and fully cured concrete only.
- Compressed air equipment must have an oil/air separator.
- Not for slab on grade in freezing climates.
|
|
Cleanup
- Ventilate area
- Confine spills
- Collect with absorbent material
- Flush area with water
- Uncured polyoxarine BRIDGE SEAL can be removed with Unitex
Citri-Clean
- Cured polyoxarine BRIDGE SEAL can only be removed
mechanically.
|
 |
 |
 |
|
First Aid
Cured polyoxarine BRIDGE SEAL is innocuous. For uncured polyoxarine:
Skin Contact:
- Remove contaminated clothing.
- Remove product with a dry cloth or paper towel.
- Wash skin area thoroughly with soap and water. (Solvents should not be used because they carry
product into the skin.)
Eye Contact:
- Flush eyes immediately with water for a minimum of 15 minutes.
Respiratory Problems:
- Seek fresh air and/or medical attention.
|
|
Cautions
- Keep away from heat, sparks and open flame.
- Flammable Liquid, Corrosive UN2924.
- Use only with adequate ventilation.
- Avoid all contact with skin and eyes.
- Avoid breathing vapors.
- For Industrial Use Only.
- Not for internal consumption.
- Keep out of reach of children.
- Use safety gloves, goggles, and NIOSH/MSHA approved organic vapor respirator if
ventilation is inadequate.
- Do not thin with solvents.
|
 |
 |
 |
 |
 |
 |